铁秦线阴极保护电位分析及改进措施  被引量:4

Potentiometric Analysis and Improvement of Cathodic Protection of Tieling-Qinhuandao Pipeline

在线阅读下载全文

作  者:孙蕾[1] 宁军 申龙涉[1] 李岩 李亮[1] 李武华[1] 何洋[1] 牛辰瑞 

机构地区:[1]辽宁石油化工大学储运与建筑工程学院,辽宁抚顺113001 [2]上海中船燃石油有限公司,上海201204 [3]中国石油管道公司沈阳调度中心,辽宁沈阳110000

出  处:《当代化工》2014年第6期1100-1102,共3页Contemporary Chemical Industry

摘  要:介绍了铁秦线埋地输油管道阴极保护现状。对阴极保护电位进行了现场测试,电位是反应管道所处状态的主要指标,因此阴极保护系统的通电电位反映了管道受干扰情况。通过测试发现多处管段处于"过保护"状态,分析可知铁秦线输油管道受杂散电流影响较为严重,针对铁秦线输油管道这一现状提出具体保护措施来延长管道的使用寿命。Present situation of cathodic protection of Tieling-Qinhuandao buried pipeline was introduced, and field test of the cathodic protection potential was carried out (Potential is the main indicator to reflect pipeline state, therefore, power-potential of the cathodic protection system can reflect the pipeline disruption). The testing results showed that multiple pipe sections were in "over-protection" status, Tieling-Qinhuandao pipeline was seriously affected by stray current, then specific protective measures were proposed to extend the life of the pipeline.

关 键 词:埋地输油管道 阴极保护电位 阴极保护系统 过保护 

分 类 号:TE832[石油与天然气工程—油气储运工程]

 