火炬气回收装置螺杆压缩机结垢原因分析  被引量:7

Cause Analysis of Fouling in Flare Gas Recycle Installation Screw Compressor

在线阅读下载全文

作  者:莫才颂[1] 王岗罡[2] 林荣雄 

机构地区:[1]广东石油化工学院机电工程学院,广东茂名525000 [2]中国人民解放军驻211厂军事代表室,北京100076 [3]茂名西南石化工程建设有限责任公司,广东茂名525000

出  处:《压缩机技术》2014年第3期55-57,61,共4页Compressor Technology

基  金:广东高校石化过程装备故障诊断与信息化控制工程中心重点实验室项目(2011A060901023)

摘  要:针对火炬气回收装置螺杆压缩机频繁发生机组出口温度过高,导致连锁停车后无法再次启动的故障情况,拆检压缩机后发现其内部结垢,转子抱死,对此原因进行分析,解决了机组运行存在的结垢问题,从而提高了机组的运行效率,保障了机组高效、安全、稳定、经济运行。Aiming at a chain situation that can't be started after stopped due to the excessive temperature outlet the unit that frequently occurred in the flare gas recycle installation screw compressor,after overhauling the screw compressor,the fouling was found inside of the machine, and the rotor stocks.This paper has analyzed the reason and the fouling problem is solved, which has improved the operating efficiency, and guaranteed the high efficient,safe,stable and economic operation of unit.

关 键 词:火炬气回收 螺杆压缩机 结垢 分析 