检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王少刚[1] 刘立强[1] 龚领会[1] 张亮[1]
出 处:《低温工程》2001年第4期29-33,38,共6页Cryogenics
基 金:国家自然科学基金资助
摘 要:二级脉冲管蓄冷器对GM/PT混合式制冷机制冷性能有较大影响。蓄冷器与脉冲管结构的布置形式对GM /PT混合式制冷机性能有着较大影响 ,蓄冷器体积与脉冲管体积之间存在着最佳比例。介绍了GM/PT混合式制冷机的结构和实验装置 ,分析了整机性能的影响因素 ,给出了不同结构与体积比下的实验降温曲线 。The regenerator of the second stage intensively affects the cooling performance of the GM/PT hybrid refrigerator Therefore the structrue of the regenerator and pulse tube is important for the cooling performance of a GM/PT hybrid refrigerator and there exists the optimum volume ratio of regenerator to pulse tube In this paper the structure and the experimental set are presented and some analyses have been done for understanding the key factor which affects the cooling performance of the refrigerator The experimental cooling down curves with different volume ratios are shown and the result of the expriment is discussed at the last
关 键 词:GM/PT 混合式制冷机 蓄冷器 制冷性能 体积 结构 脉冲管
分 类 号:TB651[一般工业技术—制冷工程]
正在载入数据...