液柱冲击式湿法脱硫装置的试验研究  被引量:4

EXPERIMENTAL STUDY OF WET FLUE GAS DESULFURIZATION IN A IMPINGE STREAM SCRUBBER

在线阅读下载全文

作  者:孔华[1] 高翔[1] 吕同波[1] 方航宇[1] 骆仲泱 岑可法[1] 

机构地区:[1]浙江大学能源清洁利用与环境教育部重点实验室,浙江杭州310027

出  处:《工程热物理学报》2001年第5期649-652,共4页Journal of Engineering Thermophysics

基  金:国家重点基础研究发展规划基金资助项目(No.G1999022201-05)

摘  要:本文提出了一种液柱冲击式湿法脱硫装置,对该装置的吸收段阻力特性和脱硫特性进行了试验研究,对试验结果进行了分析.分析发现了在塔内风速为2m/s~2.9m/s范围内,脱硫效率随塔内风速的增大而增加这一不同于其它装置的特点,得到了在塔内风速 2.6 m/s,喷液量30m3/h时脱硫效率高、阻力低这个比较经济的工况点.A wet flue gas desulfurization impinge stream scrubber was introduced. The experimen- tal results about resistance and desulfurization of the impinge stream scrubber were analyzed when limestone was used as absorbent. The results showed that desulfulization efficiency increased as gas velocity increased during gas velocity of 2m/8-2.9 m/s. The characteristic of the impinge stream scrubber was different from other scrubbers. Optimum operation parameters (gas velocity of 2.6 m/s, slurry injection of 30 m3/h) were obtained.

关 键 词:液柱冲击 脱硫效率 湿法脱硫装置 试验 

分 类 号:X701.3[环境科学与工程—环境工程]

 