混合工质J-T节流制冷机中换热器特性的试验研究  被引量:1

Experimental Study On The Behavior In The Heat Exchanger Of A Mixed Gas Joule-Thomson Cooler

在线阅读下载全文

作  者:张存泉[1] 徐烈[1] 王乾坤 邓东泉[1] 孙恒[1] 

机构地区:[1]上海交通大学制冷与低温工程研究所,上海200030 [2]江苏思露换热设备有限公司,泰州225300

出  处:《低温与超导》2001年第4期41-45,共5页Cryogenics and Superconductivity

摘  要:文中介绍了对混合工质 J- T节流制冷机中换热器特性实验研究的结果 ,指出多组分混合工质 J- T节流制冷机及其换热器设计过程中 ,混合工质组分配比对整机及换热器换热和流动有重要影响 ,选择组分配比时要统筹考虑混合工质小温差换热段的出现位置及其长度的综合影响。In this paper, an experiment set has been set up and the experimental results of the mixed gas Joule-Thomson (J-T) cooler and its heat exchanger are provided. These data show that the temperature distribution as well as the pressure distribution in the heat exchanger channels depends to a large degree on the pinch point locations in the process, which is strongly influenced by the mixture composition. Both the pinch part of heat exchanging location should be considered for the optimal design of the heat exchanger as well as for the choice of the mixture composition.

关 键 词:混合工质 J-T节流制冷机 换热器 小温差换热段 工作特性 换热性能 

分 类 号:TB651[一般工业技术—制冷工程] TB657.5

 