出 处:《电网技术》2001年第10期50-53,共4页Power System Technology
基 金:基金项目:国家电力公司资助项目(SPKJ010-19)。
摘 要:利用电磁暂态程序(EMTP),建立了相间功率控制器(IPC)的电磁暂态模型,并对IPC在短 路故障。合闸及分闸过程中出现的过电压进行了仿真计算。结果表明,调谐型IPC虽然具有 良好的短路电流限制特性,但在合闸及分闸情况下操作过电压非常高,从而限制了其实际应 用。相比较而言,非调谐型IPC的过电压要低得多,且具有一定的短路电流限制特性。从过 电压的角度来看,后者较为可取。By use of EMTP an electromagnetic model for the interphase power co ntroller(IPC)is built. The overvoltage on the IPC at connection and disconnect ion during grounding faults are calculated in detail. The results show that desp ite good current-limiting characteristic, the surge overvoltages on the tuned I PC during connection and disconnection are too high to be used in practice. Com paratively, the overvoltages on the untuned IPC are much lower, and short-circu it current can be limited evidently. The latter is preferable in practice.
分 类 号:TM743[电气工程—电力系统及自动化]