一种新型配电线路电力综合监控仪  被引量:4

A New Model Integrated Feeder Monitoring Instrument

在线阅读下载全文

作  者:刘毅[1] 鲁宝春[1] 孙莹光[1] 

机构地区:[1]辽宁工学院信息科学与工程系,辽宁锦州121001

出  处:《电力自动化设备》2002年第2期60-61,共2页Electric Power Automation Equipment

基  金:辽宁省自然科学基金资助项目 (0 0 10 81)

摘  要:给出了一种采用RS 4 85通信的方法 ,实现了在电力系统中综合监控仪与TA ,TV之间距离较远时二次侧信号的数字传送 ,该方法替代了导线直接传送的方式 ,解决了由此造成的测量精度不高和因二次侧开路烧毁TA的问题 ,并采用FFT算法实现数字滤波技术 ,能够准确计算出基波及各次谐波电压和电流。实际运行结果表明 ,提高了数据测量精度和TA运行的安全性。With the communication based on RS?485 between the integrated feeder monitoring instrument and the TA or TV in electric power system,the long distance transmission of the secondary side signals replaces the direct connection with signal cable.It solves the problems of low measuring precision and TA damage by open secondary circuit.The voltage and current of the base wave and high harmonic waves can be calculated precisely based on FFT technique.It has been proved in practice that both the measuring precision and the TA operation security and reliability are improved.

关 键 词:配电线路 电力综合监控仪 电力系统 

分 类 号:TM726[电气工程—电力系统及自动化] TM76

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象