陡河发电厂250MW机组引风机国产化改造  

Adopt Indigenous Induced Draft Fans to Retrofit250MW Generating Units in Douhe Power Plant

在线阅读下载全文

作  者:方占岭[1] 

机构地区:[1]北京大唐发电有限公司,北京100053

出  处:《中国电力》2001年第11期67-70,共4页Electric Power

摘  要:陡河电厂2台日本日立公司250MW亚临界压力机组,由于引风机影响出力进行了2次改造,第2次改造采用的是国产化引风机,实际运行表明改造后的引风机性能稳定、耗能大幅度降低,为引风机采用变速调节,进一步发挥风机节能的潜力创造了有利条件。Two Japanese Hitachi made250MW subcritical pressure generating units in Douhe Power Plant were retrofitted two times owing to derating resulted from the influence of draft fans.In the second time retrofit,the in-digenous induced draft fans were adopted.The practical operation shows that the indigenous induced draft fans can run stably,with energy consumption greatly reduced and creating favorable conditions for employing variable speed control to further take advantage of energy-saving potential of draft fans.

关 键 词:锅炉 引风机 国产化 技术改造 250MW机组 发电厂 

分 类 号:TM621.2[电气工程—电力系统及自动化] TK223.26[动力工程及工程热物理—动力机械及工程]

 