唾液中睾酮的IEMA法测定  被引量:7

IEMA Method for Measuring Salivary Testosterone

在线阅读下载全文

作  者:杨小英 陈刚毅 蒙子卿 陈然 肖晓兰 

机构地区:[1]广西壮族自治区体育科学研究所,南宁530031 [2]广西壮族自治区军分区直属门诊部 [3]广西壮族自治区肿瘤研究所

出  处:《中国运动医学杂志》2001年第4期395-396,共2页Chinese Journal of Sports Medicine

基  金:广西科技发展基金资助项目(No.桂科金9812045)

摘  要:本研究建立了唾液睾酮(ST)的IEMA(磁性微粒分离的酶联免疫)测定法。结果:平均回收率为92.35%,重复试验平均变异系数<5%,血清睾酮(T)与唾液T相关系数为:男r=0.852,P<0.001,女r=0.902,P<0.001,与其它测定唾液T方法的结果相符。本研究提示唾液T浓度可反映血浆游离T水平,在临床和体育研究中有实际应用价值。In this study , IEMA method is used to measure salivary testosterone (SI). The results show that the average rate of reclamation is 92.35% the average variation coefficient of the duplicate is < 5%; the relative coefficient of blood T and ST is r=O.852 (P<O.OO1) for male and r=O.902 (P<O.OO1) for female. The results are similar to that from the other methods of measuring ST. The ST measurement in this study can proof the free T?s level of blood. The IEMA technique is better than the other methods and is valuable in the clinical and sports research.

关 键 词:唾液睾酮 IEMA法 测定 ST 酶联免疫 