弹射座椅肩带惯性拉紧装置自动拉力适宜值的研究  被引量:2

A study on the applicable take-up strap tension for PIRD of ejection seat.

在线阅读下载全文

作  者:郭小朝[1] 刘宝善[1] 范军[1] 杨毅[1] 曹步平[1] 蹇强[1] 王荣娣[1] 刘保钢[1] 毛彦荣[1] 

机构地区:[1]空军航空医学研究所,北京100036

出  处:《中华航空航天医学杂志》2001年第3期169-171,共3页Chinese Journal of Aerospace Medicine

摘  要:目的 确定弹射座椅肩带惯性拉紧装置自动拉力适宜值范围 ,为高性能弹射座椅肩带惯性拉紧装置的国产化设计提供工效学依据。 方法  6 0名受试者靠坐在弹射座椅上 ,克服 0、2、4、6和 8kg大小的肩带后拉力 ,肩部从完全拉紧位置前倾 45 0 m m伸臂做手指按键反应。比较肩带后拉力变化对受试者按键反应时的影响。 结果 肩带后拉力等于或大于 4kg时 ,受试者前倾按键的反应时比 0 kg拉力条件下显著延长 (P<0 .0 1)。 结论 弹射座椅肩带惯性拉紧装置自动拉力应不小于1kg,不大于Objective To determine the applicable tension of take-up strap/cable for powered retracting, inertia locking, restraint harness take-up device (PIRD) of ejection seat so that to provide basis for advanced ej ection seat design. Methods Sixty male volunteers served as su bjects. They were asked to sit in an ejection seat with shoulder harness system. The reaction time (light signal-button pushing) was measured in the condition of leaning forward 450 mm from the fully retracted position against cable tensio n of 0 kg, 2 kg, 4 kg, 6 kg, or 8 kg. Results When the cable t ension was 4 kg or more, the reaction time was significantly longer than that of 0 kg (P<0.01). Conclusions It is suggested that the take -up strap/cable tension for PIRD of ejection seat should not be less than 1 kg and not more than 4 kg.

关 键 词:弹射座椅 肩带惯性拉紧装置 肩带自动拉力 飞行员损伤防护 工效学试验 

分 类 号:R857.1[医药卫生—航空、航天与航海医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象