检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]湖北省电力试验研究院,湖北省430077 [2]布鲁塞尔自由大学
出 处:《电网技术》2002年第1期39-42,共4页Power System Technology
摘 要:系统频率是大家普遍关注的电能质量指标之一。大量应用新技术对频率测量精度的要求也越来越高。近年来用于精确测量频率的新方法也常见于报道 ,但这些方法几乎都在波形畸变上做文章。文中通过理论分析和试验 ,揭示了引起频率测量偏差的主要原因是系统中的发电机出力、负荷和系统结构发生变化 。Power system frequency is one of the most important indexes of power quality and higher frequency measurement accuracy is needed by a great deal of applied technologies. At present the novel methods for accurate frequency measurement are often published in technical periodicals, but it seems as if these methods lay special emphasis on the distortion of waveform. In this paper by means of theoretical analysis and tests the basic reason causing the measurement error of frequency is revealed, that is when the output of generator, loads or the structure of power system vary, the initial phase of the measured voltage signal is suddenly changed, thus the measurement error occurs.
关 键 词:电力系统 电能质量 暂态过程 频率测量 测量误差
分 类 号:TM712[电气工程—电力系统及自动化] TM935