电子膨胀阀与毛细管在变频空调系统中的性能分析  被引量:17

Performance Comparison of Electronic Expansion Valve with Capillary Applied in Variable Frequency Air Conditioner

在线阅读下载全文

作  者:邵双全[1] 石文星[1] 李先庭[1] 彦启森[1] 

机构地区:[1]清华大学

出  处:《流体机械》2001年第12期41-43,11,共4页Fluid Machinery

摘  要:对采用毛细管与电子膨胀阀作节流装置的变频空调系统分别建立了毛细管和电子膨胀阀的数学模型和整个空调系统的仿真模型 ,用验证过仿真软件进行数值计算 ,结果表明 ,在设计工况下 ,两个系统的性能接近。若偏离设计工况 ,电子膨胀阀系统的调节特性明显好于毛细管系统。正常工作条件下采用电子膨胀阀的变频空调系统性能平均比采用毛细管的高近 1 0 %。若经常处于变化工况下的变频空调系统 。The mathematical modes of electronic expansion valve and capillary and the whole variable frequency air conditioner are established. Based on the computational results of these modes and the experimental results, the performance of variable frequency air conditioner which uses electronic expansion valve or capillary as throttling device are compared and analyzed. The compared results show that the adjustability of the electronic expansion valve is much better than that of capillary. The performance of variable frequency air conditioner using electronic expansion valve is 10% higher than that using capillary. Because the air conditioner is often operating in variable conditions, the benefit of energy saving is more noticeable when using electronic expansion valve.

关 键 词:毛细管 电子膨胀阀 变频空调器 性能分析 

分 类 号:TB657.2[一般工业技术—制冷工程] TM921.51[电气工程—电力电子与电力传动]

 