基于潜在通路分析的船用凝水泵汽蚀原因研究  被引量:4

Marine Condensate Pump Cavitation Causes Research Based on Sneak Circuit Analysis

在线阅读下载全文

作  者:覃海波[1] 金家善[1] 倪何[1] QIN Haibo;JIN Jiashan;NI He(College of Power Engineering,Naval University of Engineering,Wuhan 430033,China)

机构地区:[1]海军工程大学动力工程学院,武汉430033

出  处:《船舶工程》2018年第10期64-68,共5页Ship Engineering

基  金:国家自然科学基金面上资助项目(51179196)

摘  要:针对某型船用凝水泵切换启动时常因汽蚀原因难以建立出口压力的问题,采用潜在通路分析技术确定凝水泵发生汽蚀的原因。基于热力系统质量流动伴随能量转移的特点,完善热力系统潜在通路分析步骤,设计离心泵扬程较低时工质逆流的等效转化方法;将该型船用凝水系统转化为电路图,采用人工搜寻方式查找凝水系统网络中导致凝水泵发生汽蚀的潜在隐患。结果表明,在机组切换启动过程中,来自本台机组和相邻机组的高温级间漏水路径为造成凝水泵汽蚀的潜在通路,该结论可为凝水系统的设计和优化提供参考。Due to the fact that a certain type of marine condensate pump failed to establish outlet pressure frequently as a result of cavitation during switch starting process,the sneak circuit analysis technique is adopted to determine the cavitation causes.The sneak circuit analysis technique in the thermodynamic system is improved based on the thermodynamic characteristics of mass flow along with energy transfer,and the equivalent transformation method of centrifugal pump is designed when refrigerant flows reversely because of low lift.The marine condensate system is transformed into circuit diagram,and artificial search method is used to define the potential risks leading to cavitation of the condensate pump.The result shows that during staring process,the paths from own unit and adjacent unit with high temperature interstage leakage water are the sneak circuits resulting in the cavitation.The analysis results can provide preference for design and optimization of the condensate system.

关 键 词:潜在通路分析 船用凝水泵 汽蚀 级间漏水 

分 类 号:U664.58[交通运输工程—船舶及航道工程] TP391.9[交通运输工程—船舶与海洋工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象