超低压反渗透处理太湖水的中试分析  被引量:3

A pilot analysis for the treatment of Taihu Lake water by ultra-low pressure reverse osmosis membrane

在线阅读下载全文

作  者:魏永 姚维昊 桂波[2] 董秉直[2] Wei Yong;Yao Weihao;Gui Bo;Dong Bingzhi(School of Environmental &Safety Engineering,Changzhou University,Changzhou 213164,China;College of Environmental Science and Engineering,Tongji University,Shanghai 200092,China)

机构地区:[1]常州大学环境与安全工程学院,常州213164 [2]同济大学环境科学与工程学院,上海200092

出  处:《给水排水》2018年第12期11-16,共6页Water & Wastewater Engineering

基  金:中德水网络-从源头到用户的清洁水(SIGN)(02WCL1336A-O)

摘  要:中试以超滤过滤后的太湖水为原水,研究超低压反渗透膜在此水源条件下的运行工况,考察其对于有机物的去除效果。结果表明,在临界通量下超低压反渗透膜运行稳定,年产水量下降约为5%,反渗透对于UV_(254)、COD_(Mn)和TOC去除率分别为100%、77%和89%,对水中有机物的去除效果显著;超过临界通量运行后发现膜污染情况加重,但运行通量和污染速率却未呈线性正相关,可能与原水水质变化及难以保证的化学清洗效果有关,对于实际工程运行具有一定指导意义。The pilot ultra-low pressure reverse osmosis (RO)membrane test was carried out to analyse operation conditions and removal efficiency of organic matter using Taihu Lake water filterated by ultrafiltration membrane as raw water.The results showed that the RO membrane was stable at critical flux,and the annual water yield decreased merely 5%,the removal rate of UV254, CODMn and TOC by RO membrane were 100%,77%and 89%,respectively.RO membrane had the effective capacity to remove organic matter in water.It was obvious that the membrane fouling was aggravated with the supercritical flux operation,but the flux and fouling rate were not linearly correlated.The fluctuation of the water quality and the chemical cleaning effect which was difficult to guarantee both may be the reasons,which has certain reference for practical engineering operation.

关 键 词:太湖水 超低压反渗透膜 临界通量 有机物 膜污染 

分 类 号:X524[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象