静止式电能表脉冲群试验抗干扰能力提升  被引量:1

Enhancing the Anti-interference Ability of Electrical Fast Transient/Burst Test of Static Electricity Meter

在线阅读下载全文

作  者:李明[1] 彭筱筱[1] 江洋[1] 傅时胜 郑荐中 

机构地区:[1]浙江省计量科学研究院

出  处:《安全与电磁兼容》2018年第6期61-63,84,共4页Safety & EMC

基  金:浙江省质监局科研项目:电能表电磁兼容抗扰度试验自动检测系统研发(20160216)

摘  要:针对静止式电能表电快速瞬变脉冲群试验不合格率较高的情况,选取一款典型的单相静止式电能表进行分析,发现该表控制单元电源部分的地参考网络不完整,导致电快速瞬变脉冲群抗扰度试验不合格。优化PCB板布局后,该表符合GB/T 17215.211-2006和GB/T 17215.321-2008的电快速瞬变脉冲群抗扰度试验要求。Aiming at the fact that the static electricity meter often failed to pass the electrical fast transient/burst (EFT/B )immunity test,a typical single phase electricity meter is selected for analysis and modification.It is found that incomplete design of ground reference network in the power supply of static electricity meter control unit is the reason of unqualified EFT/B immunity test. After optimizing the layout of PCB board,the static electricity meter pass the EFT/B immunity test and complied with the requirements of the standards GB/T 17215.211-2006 and GB/T 17215.321-2008.

关 键 词:静止式电能表 电快速瞬变脉冲群 抗扰度试验 GB/T 17626.211-2006 GB/T 17215.312-2008 

分 类 号:TM933.4[电气工程—电力电子与电力传动]

 