检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王瑞荣[1] 安红海[1] 熊俊[1] 谢志勇[1] 王伟[1] Wang Rui-Rong;An Hong-Hai;Xiong Jun;Xie Zhi-Yong;Wang Wei(Shanghai Institute of Laser Plasma,Shanghai 201800,China)
出 处:《物理学报》2018年第24期92-99,共8页Acta Physica Sinica
基 金:国家自然科学基金(批准号:11575168)资助的课题~~
摘 要:针对准单色近平行光束X射线背光成像诊断需求,提出了一种用球面弯晶进行X射线衍射选单从而获取准直光束的新方案.在神光Ⅱ装置上,设计了基于球面弯晶X射线衍射选单准直光束系统,完成了该系统的安装、调试和实验应用,获得了准单色(10^(-3)<△λ/λ<10^(-2))、小发散角(<2 mrad)和大辐照匀斑(直径φ500 m)的X射线光源.同时基于衍射光学和球面镜成像理论,研究了不同布拉格角对球面弯晶X射线衍射光束发散角及其像散差的影响.结果表明,布拉格角会影响球面弯晶X射线衍射光束的发散角.用控制布拉格角范围的方法有望获得发散角优于1 mrad的近平行光束X射线光源.这种准单色、极小发散度和均匀角分布的X射线光源可应用于高分辨X射线成像诊断.In inertial confined fusion experiments, an excellent-performance and high-efficiency X-ray source plays an important role in X-ray radiography schemes. Indeed, it can be used in a variety of X-ray experimental techniques. The mono-chromaticity, flux intensity, degree of collimation (the radiation can be transported long distances without loss), and spot size of the X-ray source affect the quality of imaging. Ray-tracing simulations, which are validated by experimental results, demonstrate that high-intensity collimated X-ray beams can be produced from an isotropic X-ray source. Therefore, a method of improving the performance of an X-ray source from a laser-produced plasma is presented. A spherically bent crystal is used to collimate mono-chromatic X-rays emitted from a laser-produced plasma. Here we design a spherically bent crystal spectrometer system for collimating the laser-produced X-rays. The system performance is experimentally tested at the Shenguang Ⅱ (SGⅡ) laser facility located in Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences. The beam divergence is measured by using a metal grid placed downstream from the crystal, the metal grid that possesses wires with 60 μm in diameter and 127 μm in period. An imaging plate (IP) is placed at various distances downstream from grid. The quality of the generated beam is monitored by measuring the dimensions of the grid image formed by the beam on IP. While the narrow range of wavelength is measured with a spherically bent crystal spectrometer. Experimental results show that the spherically bent crystal spectrometer system can produce quasi-monochromatic (10-3 < △ λ/λ <10-2) X-ray beams with a high degree of collimation (less than 2 mrad divergence), uniform spot size (~500 μm), and a relative tenability in the wide spectral range. The influences of various experimental parameters on the quality of beam collimation are evaluated in two ways. They can be investigated in test experiments by representing the beam divergence dist
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.144.193.1