板坯连铸机结晶器供水系统冬季供水温度过低的改进措施  

Improvement Measures on the Over-Low Water Temperature of Water Supply System of Slab Caster Mold in Winter

在线阅读下载全文

作  者:王君[1] 许国峰[1] 吕立铭[1] 净晓星 杨亚辉[1] 张亮亮 WANG Jun;XU Guofeng;LV Liming;JING Xiaoxing;YANG Yahui;ZHANG Liangliang(Beijing Shougang Co.,Ltd.)

机构地区:[1]北京首钢股份有限公司

出  处:《首钢科技》2018年第6期29-31,共3页Shougang Science and Technology

摘  要:针对板坯连铸机结晶器供水系统在冬季供水温度偏低的问题进行了分析,并提出了改进措施。采取改进措施后,保证了板坯连铸机浇钢前的供水温度达到生产要求,使头炉板坯纵裂废品率由10%降至1%,为板坯生产的高效和稳定奠定了基础。The problem of the over-low water temperature of water supply system of slab caster mold in winter was analyzed,on which the improvement measures were proposed.After takingthe improvement measures,the water temperature before slab caster casting was guaranteed to meet the production requirements.The slab longitudinal crack ratio of the first heat was reduced from 10% to 1%,which laid a foundation for the efficiencv and stability of slab production.

关 键 词:板坯连铸机 结晶器 供水系统 供水温度 换热器 

分 类 号:TF341.6[冶金工程—冶金机械及自动化]

 