HL-2M装置环向场线圈中心轴倾角测量方法  

Metrology for tilt angle of central axis of HL-2M tokamak toroidal field coils

在线阅读下载全文

作  者:刘健[1] 蔡立君[1] 邹晖[1] 林涛[1] 李广生[1] 刘德权[1] LIU Jian;CAI Li-jun;ZOU Hui;LIN Tao;LI Guang-sheng;LIU De-quan(Southwestern Institute of Physics,Chengdu 610041)

机构地区:[1]核工业西南物理研究院,成都610041

出  处:《核聚变与等离子体物理》2018年第4期408-411,共4页Nuclear Fusion and Plasma Physics

基  金:国家磁约束核聚变能发展研究专项(2015GB105002;2015GB106002)

摘  要:通过测量HL-2M装置环向场线圈指形接头及斜面接头上的若干个点的空间坐标,利用点到平面的距离最小二乘原则,对环向场线圈的外轮廓平面进行拟合。再利用各外轮廓平面与中心轴的空间位置关系,求解得出环向场线圈中心轴倾角。通过简化模型及数值模拟求解出在不同的空间点坐标测量标准差情况下的中心轴倾角。在空间点三维坐标低测量标准差的情况下(σ=0.05mm),拟合求得倾角的相对误差为0.10‰,相对标准偏差为1.21‰。By measuring the spatial coordinates of several points on the figure joints and slice joints of the toroidal field coils on HL-2M device,the outer contour planes of the coils are fitted with the spatial data of the points by the least squared method and the tilt angle of central axis is calculated by the spatial relation between the planes and the central axis.With the simplified model and numerical simulation,the tilt angles of different spatial points with several standard deviations of measurement are calculated.The average relative error of tilt angle is 0.10‰ and the relative standard deviation is 1.21‰ with a low standard deviation of metrology (σ=0.05mm).

关 键 词:HL-2M装置 环向场线圈 中心轴倾角 

分 类 号:TL622[核科学技术—核技术及应用]

 