基于特高频时频分析的GIS盆式绝缘子缺陷分析  被引量:7

GIS Basin Insulator Defect Analysis Based on Ultra-high Frequency Time-frequency Analysis

在线阅读下载全文

作  者:廖新征 王红梅 丁登伟[3] 周电波[3] 张旭波 何宇峰 LIAO Xinzheng;WANG Hongmei;DING Dengwei;ZHOU Dianbo;ZHANG Xubo;HE Yufeng(Electric Power Research Institute,China Southern Power Grid,Guangzhou 510080,China;State Grid Siehuan Electric Power Research Institute,Chengdu 610072,China;State Grid Sichuan Electric Power Company, Chengdu 610041,China;State Grid Sichuan Maintenance Company,Chengdu 610041,China)

机构地区:[1]南方电网科学研究院,广州510080 [2]国网四川电力科学研究院,成都610072 [3]国网四川省电力公司,成都610041 [4]国网四川检修公司,成都610041

出  处:《高压电器》2019年第1期47-53,共7页High Voltage Apparatus

摘  要:为更有效在现场开展GIS局部放电检测,及时准确发现设备内部缺陷,特别是盆式绝缘子局部放电缺陷,文中研究了基于特高频时频定位分析的GIS局部放电综合定位方法。将多通道时延定位法和多通道小波时频分析法联合应用,通过局部放电特高频信号的时域和频谱变化特征,结合设备内部结构、装配工艺等情况,实现GIS局部放电综合精确定位。该方法在某500kV变电站220kV GIS带电检测中进行了应用,精确定位一处盆式绝缘子表面放电缺陷。表明文中研究的基于特高频时频定位分析的GIS局部放电综合定位方法有助于准确定位GIS内部缺陷,针对性指导设备检修工作,缩短检修时间,有效提高检修效率。For upgrading partial discharge on-site detect level of gas insulated switchgear(GIS),detecting internal defects of equipments quickly and exactly,especially partial discharge defect of basin insulator,this article researched on partial discharge synthetic location method for GIS based on ultra-high frequency time-frequency location analysis.Construction of multi-channel signals time delay location method and multi-channel time-frequency analysis method based on wavelet transform,according to the partial discharge ultra-high frequency signal time and frequency variations,GIS partial discharge synthetic location can be achieved combination of equipment internal structure and assembly process.In 220kV GIS on-site detection of one 500kV substation,this method located surface discharge of a basin insulator exactly.It has confirmed partial discharge synthetic location method for GIS based on ultra-high frequency time-frequency location analysis can locate the GIS internal defects.The application can supervise equipment maintenance pertinently,shorten equipment maintenance time and improve equipment maintenance efficiency.

关 键 词:气体绝缘开关设备 局部放电 特高频 时频定位 小波变换 

分 类 号:TM216[一般工业技术—材料科学与工程] TM855[电气工程—电工理论与新技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象