机构地区:[1]Department of Ophthalmology,Korea University College of Medicine
出 处:《International Journal of Ophthalmology(English edition)》2019年第1期73-78,共6页国际眼科杂志(英文版)
基 金:Supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF);funded by the Ministry of Education (NRF2016R1D1A1A02937018);the Bio & Medical Technology Development Program of the NRF, which is funded in part by the Korean government, the Ministry of Science, and ICT (MSIP) (NRF-2017M3A9E2056458)
摘 要:AIM: To investigate whether the response of a central hexagonal element corresponding to the macular area in conventional multifocal electroretinography(mfERG) tests was the same as that of experimental mfERG using single central hexagonal element stimulation. METHODS: Prospective, observational study. Thirty healthy subjects were included in this study. mfERG recordings were performed according to two protocols: stimulus with 37 hexagonal elements(protocol 1), and stimulus with a single central element created by deactivating the other 36 hexagonal elements(protocol 2). We compared differences between ring 1 parameters in each protocol. RESULTS: In protocol 1, the first positive component(P1) implicit time and P1 amplitude were 37.8±1.8 ms and 6.3±2.7 μV. After single element stimulation(protocol 2), double positive waves appeared. The implicit time and amplitude of P1 were 40.7±2.4 ms(P<0.001) and 9.1±3.3 μV(P=0.001), respectively. The implicit time and amplitude of the second positive component(P2) were 68.0±4.5 ms(P<0.001, compared with P1 in protocol 1) and 12.3±4.7 μV(P<0.001, compared with P1 in protocol 1), respectively. The amplitude of P2 in protocol 2 was about two times higher than that of P1 in protocol 1. CONCLUSION: mfERG responses of a central hexagonal element in a single element stimulation protocol are different from those of multiple element stimulation. The positive wave is more enhanced compared to that of the conventional protocol and it elongated into two wavelets.AIM: To investigate whether the response of a central hexagonal element corresponding to the macular area in conventional multifocal electroretinography(mfERG) tests was the same as that of experimental mfERG using single central hexagonal element stimulation.METHODS: Prospective, observational study. Thirty healthy subjects were included in this study. mfERG recordings were performed according to two protocols: stimulus with 37 hexagonal elements(protocol 1), and stimulus with a single central element created by deactivating the other 36 hexagonal elements(protocol 2). We compared differences between ring 1 parameters in each protocol. RESULTS: In protocol 1, the first positive component(P1) implicit time and P1 amplitude were 37.8±1.8 ms and 6.3±2.7 μV. After single element stimulation(protocol 2), double positive waves appeared. The implicit time and amplitude of P1 were 40.7±2.4 ms(P<0.001) and 9.1±3.3 μV(P=0.001), respectively. The implicit time and amplitude of the second positive component(P2) were 68.0±4.5 ms(P<0.001, compared with P1 in protocol 1) and 12.3±4.7 μV(P<0.001, compared with P1 in protocol 1), respectively. The amplitude of P2 in protocol 2 was about two times higher than that of P1 in protocol 1.CONCLUSION: mfERG responses of a central hexagonal element in a single element stimulation protocol are different from those of multiple element stimulation. The positive wave is more enhanced compared to that of the conventional protocol and it elongated into two wavelets.
关 键 词:MULTIFOCAL ELECTRORETINOGRAPHY focal ELECTRORETINOGRAPHY MACULAR function single element stimulation stray light effect
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...