具有谐波治理功能的TSC就地动态无功功率补偿在冶金企业应用技术的研究  被引量:5

A Study on TSC Local Static Var Compensator Functioning as Harmonic Suppression Applied to Metallurgical Plant

在线阅读下载全文

作  者:吴金钟[1] 赵玉芹[1] 苏震[1] 

机构地区:[1]安阳钢铁集团公司

出  处:《电气传动》2002年第2期54-56,共3页Electric Drive

摘  要:针对冶金企业用电设备产生的无功功率含有大量谐波无功分量的特点,合理选择无功补偿方案,提出具有谐波治理功能的TSC就地动态无功功率补偿装置的设计构思。并在安阳钢铁集团公司小型厂260机组15#机架应用该装置,功率因数提高到0.95以卜,谐波得到有效治理。In accordance with the characteristics of reactive component created by electric equipment in metallurgical plants, the paper describes a design concept of the TSC local static var compensator functioning as harmonic suppression through making reasonable select of reactive compensation proposal. The TSC unit is applied to the stand No. 15 of 260mm rolling mill in Anyang Iron & Steel Group Co., Ltd., and the power factor increased over 0. 95, thus the harmonic gets to be managed efficiently.

关 键 词:TSC 就地动态无功功率补偿 谐波治理 电力系统 冶金企业 

分 类 号:TF089[冶金工程—冶金物理化学] TM714.3[电气工程—电力系统及自动化]

 