用振动信号分析法监测变压器绕组状况  被引量:46

The Application of Vibration Method in Monitoring the Condition of Transformer Winding

在线阅读下载全文

作  者:汲胜昌[1] 王世山[1] 李清泉[1] 李彦明[1] 孙强[2] 

机构地区:[1]西安交通大学电气学院,710049 [2]西北电力试验研究院电机电器室,710054

出  处:《高电压技术》2002年第4期12-13,15,共3页High Voltage Engineering

基  金:西安交通大学博士论文基金资助项目 ( DF XJU2 0 0 0 -4 )

摘  要:振动法是诊断变压器运行中潜伏故障的一种有效手段 ,能检测出故障绕组及铁心的状况。为此 ,论述了绕组正常状态及异常时变压器绕组的振动信号特征 。The vibration method is an effective method used for on-line monitoring the power transformer delitescent fault, it can monitor not only the winding, but also the conditions of core. It is a recommended method that should be studied deeply. In this paper, a method used to measure the vibration signal of transformer's winding was brought out, the vibration signal's characteristic of a power transformer's winding in normal and abnormal conditions was described. A method to estimate the condition of winding was brought out.

关 键 词:振动信号分析法 监测 绕组 电力变压器 

分 类 号:TM407[电气工程—电器]

 