检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]北京师范大学化学系
出 处:《分析科学学报》2002年第2期111-114,共4页Journal of Analytical Science
基 金:国家自然科学基金 (No.2 9671 0 0 5 )
摘 要:本文根据 Tb3+能显著增强 Ce ( ) - SO2 - 3- NFLX体系的化学发光 ,建立了流动注射铽敏化化学发光测定诺氟沙星的新方法。本法的线性范围为 9.0× 1 0 - 9~ 1 .0× 1 0 - 6 mol/L,检出限为 4.5× 1 0 - 11mol/L。利用该法测定了诺氟沙星胶囊中诺氟沙星的含量 ,并对血清和尿样进行了回收率测定 ,回收率在 1 0 0 .4%~ 1 0 5 .7% ,结果令人满意。A new flow injection chemiluminescence method for the determination of norfloxacin was established. It is based on the chemiluminescence reaction of Ce (Ⅳ) SO 2- 3 NFLX sensitized by Tb 3+ . The calibration graph is linear for 9.0×10 -9 ~1.0×10 -6 mol/L, and the detection limit is 4.5×10 -11 mol/L. The method has been applied to the analysis of norfloxacin in capsules with satisfactory results, and the recovery for determination of norfloxacin in human serum and urine is between 100.4%~105.7%.