石墨炉原子吸收光谱法测定土壤中可交换态Cr(Ⅲ)和Cr(Ⅵ)  被引量:13

Determination of exchangeable Cr(Ⅲ) and Cr(Ⅵ) with GFAAS in soil extracts

在线阅读下载全文

作  者:池泉[1] 史建波[1] 梅俊[1] 汤志勇[1] 金泽祥[1] 熊采华[1] 董高翔[1] 

机构地区:[1]中国地质大学材料科学与化学工程学院,武汉430074

出  处:《分析试验室》2002年第2期63-66,共4页Chinese Journal of Analysis Laboratory

基  金:中国地质调查局地质调查技术方法研究项目资助 ;湖北省废物地质处置与环境保护重点实验室开放研究基金资助

摘  要:提出了流动注射离子交换石墨炉原子吸收光谱法测定土壤中可交换态Cr(Ⅲ )和Cr(Ⅵ )的分析方法 ,优化了提取方法、分离富集条件和流路参数等。分析速度为 2 0样 /h ,Cr(Ⅲ )和Cr(Ⅵ )的检出限 (3σ)分别为 2 4pg和 4.0pg ,相对标准偏差 (n =1 0 )分别为 4 7%和 5 9%。A method for determination of exchangeable Cr(Ⅲ) and Cr(Ⅵ) in soil extracts by flow injection ion exchange separation and GFAAS was developed. The conditions for extraction, ion exchange and determination were optimized. The detection limits were 24 and 4.0 pg with relative standard deviations(RSD, n =10) of 4.7 and 5.9% for Cr(Ⅲ) and Cr(Ⅵ), respectively. The proposed method was applied to the analysis of Certified Reference Material GSD-6 and a real soil sample.

关 键 词:石墨炉原子吸收光谱法 流动注射 形态分析 土壤 环境污染物 铬(Ⅲ) 铬(Ⅵ) 