检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张晓霞[1] 闫丽[1] 张梅[1] 房伯办[1] 张翠莉[1]
出 处:《武警医学》2002年第7期402-403,共2页Medical Journal of the Chinese People's Armed Police Force
摘 要:目的 确定注射器配制药液后的有效使用时间。方法 840具无菌注射器随机分成 2组 ,分别配制非抗生素药液与抗生素药液 ,每隔 1h采样培养做微生物学鉴定。结果 配制非抗生素药液的注射器 ,4h内无细菌生长 ,7h内样本污染率达 17 38% ;配制抗生类药液的注射器 ,5h内无细菌生长 ,7h内样本污染率达 3 5 7%。结论 注射器有效使用时间应在Objcctive To determine the storage life and applicability of unsealed syringes.Methods 840 syringes used in 12 clinical departments of this hospital were divided into two groups:one for dispensing antibiotic solutions and the other for non-antibiotic solutions.Samples from the unsealed syringes were collected,cultured and evaluated every one hour for identification of bacteria.Results Negative bacterial cultures were obtained during the initial 4 and 5 hours in the groups of dispensing non-antibiotic and antibiotic solutions,respectively;and the total contamination rates were 17 38% and 3.57% for the groups of dispensing non-antibiotic and antibiotic solutions,respectively,7 hours after unsealing.Conclusions Syringes should be used within 4 hours after unsealing.