一种改进的单相电路i_p-i_q谐波检测方法  被引量:3

An Improved i_p-i_q Detecting Method for Harmonics in Single-Phase Circuits

在线阅读下载全文

作  者:居茜[1] 鞠勇[1] 

机构地区:[1]南京师范大学电气与自动化工程学院,江苏南京210042

出  处:《南京师范大学学报(工程技术版)》2014年第2期24-29,共6页Journal of Nanjing Normal University(Engineering and Technology Edition)

摘  要:针对单相电路谐波的特点,以瞬时无功理论为基础,分析了单相电路ip-iq谐波检测法.综合考虑检测的精度及实时性要求,提出一种更适合单相电路谐波检测的改进方法.该检测方法在引入反馈环节、改善检测系统实时性的基础上,采用过渡带衰减速率快、频率特性好的椭圆低通滤波器代替传统的巴特沃斯低通滤波器,减少低通滤波器的延时及对检测精度的影响.利用MATLAB/Simulink进行建模和仿真,证明改进算法提高了检测精度和动态响应速度.In view of the features of harmonics in single-phase circuits,the study makes an analysis on harmonics ip-iq detection for single-phase circuits in the way of mathematics based on the instantaneous reactive power theory. Considering accuracy and real-time of the harmonics detection, a much more suitable method for harmonics in single-phase circuits is proposed. In order to improve the performance of the whole detection system, a feedback process is added to the system. With the application of the elliptic low-pass filter featuring high decay rate in transition zone and a good frequency characteristic instead of traditional Butterworth low pass filter, the method can reduce the influence of time delay of low-pass filter on the detection accuracy. The modeling and simulation of MATLAB/Simulink proves that the method improves the accuracy and speed of dynamic response.

关 键 词:单相电路 谐波检测 IP-IQ 算法 反馈 椭圆低通滤波器 

分 类 号:TM761[电气工程—电力系统及自动化]

 