检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]西南交通大学地球科学与环境工程学院,四川成都611756 [2]沈阳工业大学辽阳校区工程学院化学工程与工业系,辽宁辽阳111003
出 处:《山西化工》2014年第3期12-14,共3页Shanxi Chemical Industry
摘 要:为了充分发挥掺硼金刚石膜(BDD)电极在分析检测工业废水中重金属离子的优势,利用BDD电极作为工作电极,采用线性扫描阳极溶出伏安法测定水溶液中的铅离子,考察了硝酸、硫酸、高氯酸、盐酸4种酸体系对铅离子分析测试的影响。结果发现,在实验室条件下检测铅离子最优的支持电解质体系是硫酸,并且与其他3种酸(硝酸、盐酸、高氯酸)相比,硫酸更加稳定,不具挥发性。In order to give full play to boron-doped diamond film (BDD) electrode in the analysis and detection of heavy metal ions in industrial wastewater, this paper takes BDD electrode as the working electrode. Lead ions in aqueous solution is measured by linear sweep anodic stripping voltammetry. The impact of nitric acid, sulfuric acid, perchloric acid, hydrochloric acid to the analysis and testing of lead ions are studied. It is ultimately found that in experiments under optimal laboratory conditions lead ion detection system supporting electrolyte is sulfuric acid. Compared with the other acids (nitric acid, hydrochloric acid, perchloric acid), sulfuric acid is more stable and non-volatile.
关 键 词:掺硼金刚石膜电极 线性扫描阳极溶出伏安法 铅离子检测分析