AAS法测定纯铪中痕量元素钠  被引量:2

Determination of trace sodium in pure hafnium by AAS

在线阅读下载全文

作  者:任慧[1,2] 孙建新[1,2] 

机构地区:[1]中航工业北京航空材料研究院航空材料检测与评价北京市重点实验室,北京100095 [2]中航(试金石)检测科技有限公司,北京100095

出  处:《分析仪器》2014年第4期64-67,共4页Analytical Instrumentation

摘  要:研究了用AAS法测定纯铪中痕量元素钠。优化了原子吸收光谱测量条件,研究了酸及其用量,基体铪对测定钠的影响,编制了分析方法。测量钠的相对标准偏差不大于5.18%,测定范围为0.001%~0.005%,方法检出限为0.0041μg/m L。结果表明,本法不仅准确可靠而且简便快速。A method for the determination of trace Na in pure hafnium by AAS was developed .The meas-uring conditions of AAS were optimized .The influences of the amount of acid ,and hafnium on the deter-mination of Na in pure rhenium were investigated .The relative standard deviations of the results obtained by the method were less than 5 .18% ,the appropriate concertration range was 0.001%-0.005% and the detection limit was 0.0041μg · mL -1 .

关 键 词:原子吸收光谱   

分 类 号:TG115.3[金属学及工艺—物理冶金]

 