检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]浙江大学空间结构研究中心,浙江杭州310058 [2]碧桂园物业发展有限公司,广东佛山528312
出 处:《浙江大学学报(工学版)》2014年第7期1202-1208,共7页Journal of Zhejiang University:Engineering Science
基 金:国家自然科学基金资助项目(51178414)
摘 要:为了反映钢制储液罐的渐进失效趋势并合理地量化弹塑性地震力,采用流固耦合系统的单向动力推覆分析,建立反应谱层次的幂次失效模型.根据该模型构建等向强化的广义本构关系,在特定延性下迭代求解地震力折减系数Ry.结果表明,幂次失效模型下的地震力折减系数变异性较小,双线性滞回模型下的地震力折减系数会导致过于保守或偏于危险的地震力折减.选取40条最不利地震动并按场地分类,幂次失效模型下的地震力折减系数的均值略低于目标延性值,更符合长周期结构的等位移准则.GB50341与SH/T3026规定的地震力折减系数高于API650与EN1998-4,建议将地震力折减系数调整至2.0,应进一步细化边界条件的影响.A power failure model in response spectrum format was conducted through unidirectional dynamic pushover analysis of fluid-solid coupled system in order to reflect the progressive failure trend of liquid storage tanks and rationally quantify the elastoplastic seismic force.Then generalized constitutive relations with isotropic hardening were established,and seismic force reduction factor Rywas iteratively solved under specific ductility values.Results show that seismic force reduction factor based on power failure model has slight variability,and seismic force reduction factor based on bilinear hysteretic model will cause overconservative or over-risky seismic force reduction.Forty severest ground motions were selected and classified by site types.The mean values of Rybased on power failure model were slightly lower than target ductility values,which is more in line with equal displacement rule of long-period structures.The specified seismic force reduction factor values in GB50341and SH/T3026are higher than those in API650and EN1998-4.The suggestion is that Ryshould be adjusted to 2.0and the effects of boundary conditions need to be further refined.
关 键 词:钢制储液罐 弹塑性 动力推覆 幂次失效 地震力折减
分 类 号:TU33[建筑科学—结构工程] TE972[石油与天然气工程—石油机械设备]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.112