检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]华东电力设计院,上海市200001 [2]上海电缆研究所,上海市200093
出 处:《电力建设》2014年第8期108-112,共5页Electric Power Construction
摘 要:铝包钢线具备钢线的优越抗拉性能和铝的良好导电性能,耐腐蚀性能大大优于镀锌钢线,耐热性能良好。采用20.3%IACS的铝包钢线代替镀锌钢线作为加强芯,与高导电率铝线组成节能导线,比同规格的钢芯高导电率铝绞线机械性能有所提高,弧垂特性稍好,耐腐蚀性能明显提高,而电晕特性、电磁环境特性保持不变;尤其适用于沿海和重污秽地区,能够延长导线的使用寿命;应用于钢比为7%、9%、13%的导线时使电阻率分别下降1.2%、1.6%、2.3%以上。在500 kV线路典型算例中,导线费用增加部分约4年即可从降低的电能损耗中收回,此后每年能有很大的经济效益,值得推广。Aluminum-clad steel wire has the advantages of the good tensile strength of steel and the good conductivity of aluminum,and has much better anti-corrosion performance than zinc-coated steel wire,as well as the good thermal resistance.By replacing zinc-coated steel wire with 20.3% IACS aluminum-clad steel wire,and using high conductivity aluminum conductors,the composite energy-saving conductor has better mechanical performance,better sag characteristics, and better anti-corrosion performance than the zinc-coated steel reinforced cable, while keeps the same corona and electromagnetic environment characteristics.It is especially suitable for coastal or heavy polluted area.With using ACSR of 7%,9%,13% steel ratio,the resistivity of cable is reduced by 1.2%,1.6%,2.3%,respectively.Taking 500 kV transmission line as typical example,the saved energy loss can cover the extra conductor cost in 4 years,and give good financial benefit in following years.The aluminum-clad steel reinforced cable is worth popularizing.
分 类 号:TM751[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117