冷氨法烟气CO_2捕集工艺废水污染控制  

Study on the Waste Water Control in Aqueous Ammonia Process for CO_2 Capture

在线阅读下载全文

作  者:姬存民[1] 左启银[1] 朱家骅[1] 商剑锋[2] 崔文鹏[2] 刘项 

机构地区:[1]四川大学化学工程学院,四川成都610065 [2]中石化中原油田普光分公司,四川达州635000 [3]中石化南京工程公司,江苏南京211100

出  处:《四川化工》2014年第4期51-53,共3页Sichuan Chemical Industry

基  金:国家科技支撑计划课题(2013BAC12B01)

摘  要:针对冷氨法烟气CO2捕集尾气脱氨过程绘制了低温低浓度的NH3-CO2-H2O体系气液平衡相图,利用相图对废水代洗水的的两级水洗脱氨系统进行了分析,结果表明该系统可以达到尾气NH3浓度<10ppm,同时达到废水氨氮浓度<15mg/L的环保指标。Referring to the low temperature and low concentration conditions, the VLE curves of NHs-CO2- H2O system was draw for the ammonia removal in the chilled ammonia based CO2 capture process. On the basis of graphic curves of VLE, two stage ammonia washing process by using waste water replacing regen- erated water was analyzed, The results show that both the ammonia pollution control standards of 10 ppm for exhaust gas and 15 mg/L for wastewater can be reached by using the two stage ammonia washing process.

关 键 词:CO2捕集 尾气氨含量 氨氮废水 气液平衡 污染控制 

分 类 号:X703[环境科学与工程—环境工程]

 