检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]西安森宝电气工程有限公司,陕西西安710119
出 处:《电力电容器与无功补偿》2014年第4期9-14,共6页Power Capacitor & Reactive Power Compensation
摘 要:针对某金属硅厂矿热炉短网布置、炉体和炉料等不平衡导致三相负荷电流不平衡,严重危及了当地110 kV变电站的正常运行,提出使用TCT型SVC装置对矿热炉进行分相功率补偿,治理三相电流不平衡的方法,并通过PSCAD仿真试验验证了该方法的可行性和高效性。As for normal operation of 110 kV substation which is in serious danger due to unbalance of three-phase load current caused by short network configuration of certain silicon metal mines arc furnace and unbalance of furnace body charge, a method on using thyristor controlled transformer (referred to TCT) type static var compensator (referred to SVC) to perform phase power compensation of the arc furnace and control unbalance of three-phase current is raised. Both feasibility and high efficiency of the method is verified by PSCAD simulation test.
关 键 词:矿热炉 三相负荷不平衡 三相电流不平衡 晶闸管控制变压器(TCT) 静止无功补偿(SVC)
分 类 号:TM761.12[电气工程—电力系统及自动化]