检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:周义刚[1] 牛翔宇[1] 薛泽海[1] 刘卫平[1] 边疆[1]
机构地区:[1]天津市电力公司电力科学研究院,天津300384
出 处:《热力发电》2014年第8期116-119,共4页Thermal Power Generation
摘 要:准确地进行锅炉受热面壁温计算是评估其安全状况的重要条件。针对传统锅炉管壁温度计算模型效率低、适应性差以及只能对某一特定炉型进行计算等问题,建立了能够用于不同炉型及各受热面形式的通用电站锅炉壁温计算系统,并进行了实际验证,得到的锅炉管壁温度计算结果与实际温度误差小于0.5%。Accurate temperature calculation for heating surface has important means of safety evaluation.As the conventional temperature calculation model of boiler tube wall has low efficiency,poor suitability and only be aimed at a particular type furnace,the conventional calculation model was modified to develop a temperature computing system for different furnace types and heating surface types.Moreover,the new calculation method was verified through actual application.The results show the relative error of the calculated temperature and the actual temperature is below 0.5%.
分 类 号:TK229.6[动力工程及工程热物理—动力机械及工程]