高压直流换流阀断续电流试验方法研究  被引量:2

Research of Intermittent Current Test Method for HVDC Thyristor Valves

在线阅读下载全文

作  者:刘朴[1] 许钒[1] 胡治龙[1] 张长春[1] 黄熹东[1] 张腾[1] 

机构地区:[1]西安高压电器研究院有限责任公司.西安710077

出  处:《高压电器》2014年第8期8-13,共6页High Voltage Apparatus

摘  要:换流阀作为直流输电系统的核心设备,考核其性能的试验方法至关重要。笔者依据高压直流换流阀试验标准,讨论了国内外著名实验室关于直流换流阀运行试验中周期性触发和熄灭试验内容之一的断续电流试验方法,给出目前西高院换流阀断续电流的几种经受了工程验证的试验方法,并对几种试验方法进行了比较,为感兴趣的工程科技人员更好地理解标准对断续电流试验要求、实际运行工况以及试验考核关键点之间的关系提供了参考。Thyristor valves is the key equipments of the HVDC transmission system, performance assessment testing method is very important. Based on HVDC thyristor valves standards, the domestic and foreign famous labs about the intermittent current testing methods, one of periodic trigger and extinguishing experiment content of HVDC thyristor valves operation testing are discussed, and several intermittent current testing methods of HVDC thyristor valves in XIHARI are proposed. As interested in engineering science and technology personnel's reference, standards for interrupting current test requirements, the actual operating conditions and test appraisal the relationship between the key points are provided.

关 键 词:特高压 换流阀断续电流试验 运行试验系统 试验方法 直流输电 

分 类 号:TM721.1[电气工程—电力系统及自动化]

 