硝酸装置低压反应水冷器的优化改造  

Optimization and Renovation of Low-Pressure Reactor Water Cooler for Nitric Acid Unit

在线阅读下载全文

作  者:黎志敏[1] 

机构地区:[1]杭州龙山化工有限公司,浙江杭州310053

出  处:《化肥工业》2014年第4期39-41,共3页Chemical Fertilizer Industry

摘  要:介绍了双加压法硝酸装置低压反应水冷器的运行工况及特性,分析了水冷器腐蚀的原因主要为温差应力腐蚀、高温冷凝稀硝酸冲刷和Cl-聚集的应力腐蚀。针对腐蚀原因,提出了采用内孔焊先进制造工艺、改变设备布置形式等优化改造措施,能够有效解决目前存在易腐蚀的问题。The operation conditions and characteristics of low-pressure reactor water cooler for nitric acid unit is introduced , and the causes for corrosion of the water cooler is analyzed , they are differential temperature stress corrosion , high temperature condense dilute nitric acid erosion and stress corrosion of Cl - gathering .Based on corrosion causes , optimization and renovation measures are proposed , including using advanced inner hole welding technology , changing layout of equipment and so on, these can solved corrosion problems effectively .

关 键 词:双加压法 硝酸 水冷器 优化改造 

分 类 号:TQ111.26[化学工程—无机化工]

 