詹姆斯·韦伯太空望远镜中红外仪低温制冷系统的流程分析及优化  被引量:2

Analysis and optimization of MIRI cryogenic system on James Webb Space Telescope

在线阅读下载全文

作  者:刘东立[1] 陶轩[1] 孙潇[1] 甘智华[1] 

机构地区:[1]浙江大学能源工程学系制冷与低温研究所,杭州310027

出  处:《低温工程》2014年第4期5-10,30,共7页Cryogenics

基  金:国家自然科学基金(51176165)

摘  要:针对詹姆斯·韦伯太空望远镜的中红外仪冷却系统中J-T节流循环的热力学计算分析结果表明,适当地降低末级预冷温度、提高压比和提高末级间壁式换热器效率是J-T节流循环制冷性能提升的关键。考虑该复合型低温制冷机的整机效率,结合当前脉管制冷机和驱动J-T节流循环的线性压缩机的性能水平,探讨了预冷温度和J-T节流循环压力的优化方法。计算结果表明优化后的预冷温度和J-T节流循环压力使复合型低温制冷机的性能高于原预冷温度和J-T节流循环压力下性能的计算值,实际具体的脉管制冷机和J-T节流循环压缩机性能是实现准确优化的必要条件。A hybrid cryocooler consisting of a three-stage pulse tube cryocooler and a J-T cryocooler was employed as the MIRI cryogenic system in the James Webb Space Telescope. Based on the J-T loop of the hybrid cryocooler,the thermodynamic calculation results show that the appropriate lower precooling temperature,higher pressure ratio and higher recuperator effectiveness are the keys to improve the performance of the J-T loop. Taking the overall efficiency of the hybrid cryocooler into account,the optimization of precooling temperatures and pressures of the J-T loop is discussed referring to the current level of the performance both of the pulse tube cryocoolers and the linear compressors of the J-T loops. The optimized precooling temperature and pressures can make the the performance of the hybrid cryocooer better than that calculated from the origin parameters. The actual performance of the pulse tube cryocooler and the J-T compressor is a requirement for accurate optimization.

关 键 词:太空望远镜 中红外仪 复合型低温制冷机 J-T节流 脉管制冷机 

分 类 号:TB651[一般工业技术—制冷工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象