Micellar sensitized catalytic kinetic spectrophotometry for highly accurate and reproducible determination of Ⅴ(Ⅳ) and Ⅴ(Ⅴ)  被引量:2

Micellar sensitized catalytic kinetic spectrophotometry for highly accurate and reproducible determination of Ⅴ(Ⅳ) and Ⅴ(Ⅴ)

在线阅读下载全文

作  者:Ramazan Grkan Can Emektas 

机构地区:[1]Department of Chemistry,Faculty of Sciences,University of Cumhuriyet

出  处:《Rare Metals》2014年第4期466-478,共13页稀有金属(英文版)

基  金:financially supported by the Scientific Research Projects Council in Cumhuriyet University(No.294)

摘  要:A highly accurate and reproducible micellar sensitized kinetic method was proposed for determination of V(VI). The method is based on its catalytic effect on the oxidation of Coomassie brilliant blue R 250 (CBB+) by bromate at pH 2.0. The reaction was monitored spectro- photometrically by measuring absorbance change with a fixed-time method of 5 min at 594 and 552 nm with and without surfactant. The variables influencing the calibra- tion sensitivity were extensively investigated, and the optimal conditions were established. The linear calibration range was 10-1,600 μg.L-1 with a relative SD ranging from 0.35 % to 3.35 % (for five replicate measurements of 75, 500, 1,000, and 1,500 μg.L-1) and a detection limit of 3.8 μg.L-1. The selectivity was also investigated, and greatly enhanced by suitable masking agents. The method was successfully applied to the analysis of V(IV) in pre- sence of excess V(V) up to 25 fold in environmental waters with the recoveries of 100.0 %-102.8 % for V(IV) and 95.7 %-99.7 % for total V. Its accuracy was validated by analysis of certified reference material via the present kinetic method and standard flame atomic absorption spectrometric method after extractive preconcentration with good agreement between certified and found values.A highly accurate and reproducible micellar sensitized kinetic method was proposed for determination of V(VI). The method is based on its catalytic effect on the oxidation of Coomassie brilliant blue R 250 (CBB+) by bromate at pH 2.0. The reaction was monitored spectro- photometrically by measuring absorbance change with a fixed-time method of 5 min at 594 and 552 nm with and without surfactant. The variables influencing the calibra- tion sensitivity were extensively investigated, and the optimal conditions were established. The linear calibration range was 10-1,600 μg.L-1 with a relative SD ranging from 0.35 % to 3.35 % (for five replicate measurements of 75, 500, 1,000, and 1,500 μg.L-1) and a detection limit of 3.8 μg.L-1. The selectivity was also investigated, and greatly enhanced by suitable masking agents. The method was successfully applied to the analysis of V(IV) in pre- sence of excess V(V) up to 25 fold in environmental waters with the recoveries of 100.0 %-102.8 % for V(IV) and 95.7 %-99.7 % for total V. Its accuracy was validated by analysis of certified reference material via the present kinetic method and standard flame atomic absorption spectrometric method after extractive preconcentration with good agreement between certified and found values.

关 键 词:Vanadium speciation Kineticspectrophotometry BROMATE Coomassie brilliant blue R250 Micellar effect 

分 类 号:O657.3[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象