Influence of tube voltage on digitized image qualityof patients exposed to occupational dust: phantoms and clinical studies  

Influence of tube voltage on digitized image qualityof patients exposed to occupational dust: phantoms and clinical studies

在线阅读下载全文

作  者:Wang Xiaohua Liu Dongsheng Xuan Xiao Duan Jianghui Yuan Huishu 

机构地区:[1]Department of Radiology, Peking University Third Hospital,Beijing 100191,China [2]Department of X-ray R&D, Beijing General Electric Medical Equipment Limited Company, Beijing100176,China [3]Health Science Center, Peking University, Beijing 100191,China

出  处:《Chinese Medical Journal》2014年第16期2940-2944,共5页中华医学杂志(英文版)

摘  要:Background High-voltage analog X-ray examination is a main tool for pneumoconiosis,which is challenged by digital radiography (DR).The tube voltage of DR chest films required for diagnosis and staging of pneumoconiosis is concerned technically.We investigated the influence of the tube voltage on chest X-ray DR image quality of patients exposed to occupational dust.Methods DR images of the CDRAD2.0model,an anatomical chest phantom,and 136 exposed workers were analyzed at different tube voltages by threereaders.Image quality factors (IQF) were calculated and compared using the CDRAD2.0 model.DR images of ten anatomic positions were scored against those of the high-kilovolt chest films in anatomical phantom and clinical cases,and differences in scores were analyzed.Results In the CDRAD2.0 model,all three readers had a minimal IQF at 120 kV (mean:22.25 kV).The differences in the mean IQF of DR images at different tube voltages was significant (F=13.78,P〈0.001).The IQF of DR imaging at 120 kV was similar to high kilovolt analog imaging (t=-0.58,P〉0.05).In the anatomic phantom and clinical cases,the DR images at 120 kV were closest in anatomical detail to the high W analog images,and the means were similar (P〉0.05).Conclusions Among different tube voltages,DR image quality is closest to the high kilovolt analog images at 120 kV in patients exposed to occupational dust.Background High-voltage analog X-ray examination is a main tool for pneumoconiosis,which is challenged by digital radiography (DR).The tube voltage of DR chest films required for diagnosis and staging of pneumoconiosis is concerned technically.We investigated the influence of the tube voltage on chest X-ray DR image quality of patients exposed to occupational dust.Methods DR images of the CDRAD2.0model,an anatomical chest phantom,and 136 exposed workers were analyzed at different tube voltages by threereaders.Image quality factors (IQF) were calculated and compared using the CDRAD2.0 model.DR images of ten anatomic positions were scored against those of the high-kilovolt chest films in anatomical phantom and clinical cases,and differences in scores were analyzed.Results In the CDRAD2.0 model,all three readers had a minimal IQF at 120 kV (mean:22.25 kV).The differences in the mean IQF of DR images at different tube voltages was significant (F=13.78,P〈0.001).The IQF of DR imaging at 120 kV was similar to high kilovolt analog imaging (t=-0.58,P〉0.05).In the anatomic phantom and clinical cases,the DR images at 120 kV were closest in anatomical detail to the high W analog images,and the means were similar (P〉0.05).Conclusions Among different tube voltages,DR image quality is closest to the high kilovolt analog images at 120 kV in patients exposed to occupational dust.

关 键 词:phantomsimaging PNEUMOCONIOSIS radiography  digital 

分 类 号:R135.2[医药卫生—劳动卫生]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象