作 者:赵国良[1] 郑亦军[1] 李勇 周刚 朱乐明[1] 毛树印 杨龙[1]
机构地区:[1]南京军区疾病预防控制中心医学防护所 [2]94625部队卫生所 [3]65535部队医院
出 处:《医学研究生学报》2014年第8期847-850,共4页Journal of Medical Postgraduates
基 金:南京军区医药卫生科研基金(12MA118)
摘 要:目的放射诊疗设备的迅速发展对防护设施提出了更高的要求,文中通过调查放射诊疗设备机房防护现状,提出相应对策,从而提高放射防护水平。方法对华东地区33家医疗单位的拍片机、CT机、伽玛刀、加速器、后装治疗机等设备的许可证及档案进行现场调查,对设备所在机房的面积、墙壁厚度、防护门铅当量及防护泄漏水平进行检测,并依据相应的国家标准进行评价和分析。结果 1三甲医院放射诊疗设备检查合格率分别为后装机(100%)、拍片机(99%)、胃肠机(98%)、CT机(98%)、加速器(98%)、伽玛刀(97%)、DSA(94%)、PET-CT(94%)、ECT(90%)、牙片机(84%)和钼靶机(84%);其他等级医院为加速器(100%)、拍片机(91%)、CT机(89%)、胃肠机(80%)、DSA(80%)和伽玛刀(80%)。2核医学、放射诊断和放射治疗3种类型设备机房外辐射泄漏检测合格率分别为100%、99%、97%。结论华东地区33家医疗单位放射诊疗设备及设施防护水平有待加强,应加强监督,落实规章制度,严格执行放射防护评价制度,加强放射防护法规和技能的培训。Objective The rapid development of radiation equipment has put forward higher requirements for protective facil -ities.The aim of this study was to research the radiation protection status of treatment equipment room in thirty -three medical units from East China area , and to put forward corresponding countermeasures to improve the level of radiation protection . Methods The li-cense and archival of X-ray machine, CT, gamma knife, accelerator, after loading therapy machine were surveyed in the thirty-three medical units .The engine room size , wall thickness , lead equivalent of protection doors , and leakage level of equipment were detec-ted.All the data were evaluated and analyzed on the basis of the corresponding national standards . Results ①The inspection pass rates of radiation treatment equipments in the first class hospitals were afterloader (100%), X-ray apparatus(99%), gastrointestinal machine(98%), CT(98%), medical processing accelerator (98%), gamma knife(97%), DSA(94%), PET-CT(94%), ECT (90%), dental engine(84%)and molybdenum target drone (84%).The inspection pass rates of radiation treatment equipments in other class hospitals were medical processing accelerator (100%), X-ray apparatus(91%), CT(89%), gastrointestinal machine (80%), DSA(80%) and (80%) gamma knife.②The qualified rates of the leakage radiation levels of radiation therapy , diagnostic radiology and nuclear medicine were 100%, 99% and 97%. Conclusion The radiation protection of treatment equipments and facilities in thirty-three medical units from East China area needs to be strengthened . We should strengthen supervision , implement the rules and regulations , strictly perform the regulation of radiation protection evalua-tion, and strengthen the training of radiation protection regulations and skills .
分 类 号:R143[医药卫生—公共卫生与预防医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.52