射线透照等效系数测试方法分析  被引量:4

Analysis of Radio Graphic Equivalent Factor Test Method

在线阅读下载全文

作  者:蔡闰生[1] 袁生平[1] 任华友[1] 

机构地区:[1]航天材料及工艺研究所,北京100076

出  处:《宇航材料工艺》2014年第4期86-89,共4页Aerospace Materials & Technology

摘  要:为获得不同透照电压下不同标准材料的射线透照等效系数,以50 kV透照电压为例,以钛为标准材料,揭示了同时透照法和图像法两种等效系数的测试方法。通过对同时透照法步骤及存在问题的分析,引入了解决问题的阶梯扩展和厚度校正两种手段。在等效系数图像法的分析过程中,明确了曝光曲线种类和黑度选取的原则,阐述了曝光曲线与图像法的关系,结合数学手段运用,获得了等效系数与透照电压相关,但不随曝光量改变而变化的结论。In order to get radiographic equivalent factor for different materials under different transillumination voltage,the essay used two testing methods of simultaneous transillumination and exposure curve graphic in the environment of 50 kV transillumination voltage,using titanium as standard material.Through the analysis of the steps and problems of simultaneous transillumination method,the essay took in two means of ladder extension and thickness verification as the settlement of the problem.Though the analysis of exposure curve graphic method,the essay affirmed the rules on choosing exposure curve and blackness,explained the relationship between the exposure curve and graphic method.Combined with mathematical tools,the essay obtain the conclusion that the equivalent factor is associated with transillumination voltage,but will not change with the exposure quantity.

关 键 词: 标准材料 等效系数 测试方法 

分 类 号:TM930.12[电气工程—电力电子与电力传动]

 