检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李鹏[1] 宋静[1] 王明昊[1] 李雪波[1] 刘锁利[1] 郭晓东[2]
机构地区:[1]河北省保定市第一医院骨科,河北保定071000 [2]解放军第302医院,北京100039
出 处:《现代生物医学进展》2014年第27期5328-5330,共3页Progress in Modern Biomedicine
摘 要:目的:探讨股骨近端抗旋转髓内钉与第三代Gamma钉治疗股骨转子间骨折的临床疗效,为骨科手术提供可借鉴的资料。方法:2009年4月-2013年3月期间在我院接受治疗的40例股骨转子间骨折患者,随机分为两组。其中,PFNA组20例患者采用股骨近端抗旋转髓内钉质量,而Gamma 3组20例患者采用第三代Gamma钉治疗。观察并比较两组患者的手术时间、影像增强剂时间和失血量,术后评价复位质量和内置物位置,在随访中,记录术后并发症,包括股骨干骨折、切出、再次手术、肺炎、尿路感染、脑梗塞、心肌梗塞和褥疮性溃疡等。另外,用Parker-Palmer活动评分系统评价行走能力。结果:PFNA和Gamma 3组在手术时间、影响增强剂时间和失血量上没有差异(P>0.05);Gamma 3组病例复位质量要好于PFNA组,差异显著且具有统计学意义(P<0.05);两组在内置物位置、行走能力和术后并发症上没有显著差异(P>0.05)。结论:PFNA与Gamma 3治疗股骨转子间骨折具有很好的安全性和有效性,但Gamma3可获得更好的复位质量,应进一步在临床推广。Objective: Proximal femoral nail antirotation (PFNA) and third-generation Gamma nail (Gamma 3) are widely used in the treatment of intertrochanteric fractures. However, it remains unclear which device achieves better clinical and radiographic outcomes when treating intertrochanteric fractures. Methods: 40 patients with the intertrochantefic fractures who were treated by PFNA in our hospital from April 2009 to March 2013 were selected as the PFNA group, and another 20 patients with either who were treated by Gamma 3 were chosen to be the Gamma 3 group. Then the operative time, image intensifier time and amount of blood loss were recorded. Following surgery, we assessed reduction quality and implant position. At the final follow-up, postoperative complications, including femoral shaft fracture, cutout, reoperation, pneumonia, urinary tract infection, cerebral infarction, cardiac infarction and decubital ulcer, were recorded. In addition, walking ability was assessed by the Parker-Palmer mobility score. Results: No difference was found in the operative time, image intensifier time and amount of blood loss between patients treated with PFNA and those treated with Gamma 3. The reduction quality of fractures treated with Gamma 3 was better than those treated with PFNA. However, there were no significant differences in implant position, walking ability and postoperative complications between the two groups. Although Gamma 3 resulted in better reduction quality, it did not provide any advantages in walking ability and postoperative complications when compared with PFNA. Conclusion: Therefore, we conclude that both PFNA and Gamma 3 are safe and reliable devices for the treatment of intertrochanteric fractures.
关 键 词:股骨近端抗旋转髓内钉 第三代Gamma钉 股骨转子间骨折
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222