作 者:Watthana Suebkinom Bunlung Neammanee
出 处:《Journal of Energy and Power Engineering》2014年第8期1475-1481,共7页能源与动力工程(美国大卫英文)
摘 要:This paper proposes the control of a grid side converter under unbalance voltage conditions for wind turbine system. The control technique is designed to operate under unbalance voltage by independent control between positive and negative components. The converter will regulate the DC link voltage at the specific value (650 V). To verify an operation of the proposed control, the simulation is conducted by MATLAB/SIMULINK program. The experiments are conducted on a 5 kW system composed of wind turbine simulator, machine side converter and the propose grid side converter for operation under unbalance voltage. By comparing the simulation experimentation results, it can be shown that the proposed control can be continuously operating through an extremely sag voltage without damage. Moreover the proposed control can deliver power to the grid and regulate DC link voltage under unbalance voltage.
关 键 词:Grid side converter unbalance voltage positive component negative component