600 MW超临界汽轮机机组冷端的优化改造  被引量:2

Improvement for 600 MW Supercritical Steam Turbine Cold End

在线阅读下载全文

作  者:汪杰斌 

机构地区:[1]国投宣城发电有限责任公司运行部,安徽宣城242052

出  处:《热力透平》2014年第3期216-218,230,共4页Thermal Turbine

摘  要:对某发电公司1号超临界机组(600 MW)汽轮机冷端设备老化和双背压凝汽器抽空气系统不合理进行了分析并提出改造和优化方案。通过该机组冷端改造和优化方案的实施,该机组全年真空约提高0.816kPa,降低发电煤耗1.67 g/(kw·h),节约标煤6346 t,节约资金561.621万元。通过全年的运行经验表明,该项改造取得了显著的经济效益。For a No. 1 supercritical unit 600 MW steam turbine in power plant, the situation of cold end equipment aging and unreasonable air-extraction system for double back pressure condenser is analyzed, and the optimization scheme is put forward. Through the implementation of the unit's cold end modification and optimization scheme, the unit annual vacuum increases about 0. 816 kPa, reducing power coal consumption of 1.67 g/kW · h, which saves 6 346 tons of standard coal, with total amount of 5. 6 million Yuan. The operation experience shows that this retrofit has achieved remarkable economic benefits.

关 键 词:节能降耗 汽轮机冷端 抽空气系统 机组真空 

分 类 号:TK267[动力工程及工程热物理—动力机械及工程]

 