肝素抗凝血浆用于生化检验的可行性分析  被引量:17

Feasibility analysis of heparin anticoagulant blood plasma used for biochemical clinical laboratory

在线阅读下载全文

作  者:徐震[1] 吴继华[1] 钮丽萍[1] 陆小芳[1] 朱同华[1] 沈国荣[1] 

机构地区:[1]南通大学附属吴江医院检验科,江苏吴江215200

出  处:《安徽医药》2014年第11期2154-2156,共3页Anhui Medical and Pharmaceutical Journal

摘  要:目的通过观察两种对血液处理方式的生化检验,分析肝素抗凝血浆在生化检验中是否可行,为奠定肝素抗凝血浆在检验科的地位做好准备。方法将随机并自愿受试的、生理情况正常的120例做生化检验的患者选出,所有患者均接受采血6 m L,分别注入两种颜色(标签颜色分红、蓝两组颜色,红色为真空普通试管,蓝色为真空肝素抗凝血浆试管)不同的试管,分别进行生化分析,仪器型号为西门子2400,生化分析完毕后将两组所测定值进行统计学处理。结果通过观察,两组分别得到了测定值,血清组和血浆组组间比较,存在差异的(P<0.05)指标有K+、Na+、GLU、LDH、CO2,而相比之下所剩下的其他指标则差异不大(P>0.05),如:Cl-、CR、BUN、AST、UA、B-AMY、CK、CK-MB、LPS。结论分析结果证实了肝素抗凝血浆在生化中的可行性,为检验科今后应该继续使用该技术做了更为确定性的表达,血液凝固过程延长、标本分离时间缩短、血液互溶情况减少等都是肝素抗凝血浆在生化中应用的特异性优点,该技术推广可以更为清晰准确的测量出指标的浓度,关于钾离子测量的微小差异也能因此而得到纠正,故在临床中反应出患者最真实的病情,这一点是十分有意义的。Objective To analyze the feasibility of using heparin anticoagulant blood plasma in biochemical clinical laboratory by ob-serving biochemical test of two kinds of blood processing. Methods We randomly picked out 120 voluntary subjects with normal con-dition from biochemical examination patients,who were drawn 6 ml of blood,which then was put into vacuum tubes with different colors ( red and blue,the red ones were vacuum test tubes,while the blue ones were vacuum heparin anticoagulant plasma tubes) ,and then bi-ochemical analyses were made respectively with the instrument Siemens 2400. Finally the data of two groups were processed by statis-tics. Results In comparison of the serum group and the plasma group,there were differences(P〈0. 05) in index of K+,Na+,GLU, LDH,CO2,while there were no significant differences in the rest of other indicators (P〉0. 05) including Cl-,CR,BUN,AST,UA,B-AMY,CK,CK-MB,and LPS. Conclusions The results of the analysis confirmed the feasibility of heparin anticoagulant used for plas-ma biochemical test. Extension of blood coagulation process,shortening separation time and reduction of blood miscibility are the bio-chemical specific advantages of heparin anticoagulant blood plasma in the applications. The technology can measure the index concentra-tion more clearly and accurately,and subtle difference of potassiumion measurement may be corrected. Therefore,it may reflect the real condition of patients in clinic,which is very meaningful.

关 键 词:肝素抗凝血浆 生化检验 可行性分析 

分 类 号:R446.1[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象