胶体滴定测定PAC电荷密度的实验研究  被引量:4

Experimental research on colloid titration determination of PAC charge density

在线阅读下载全文

作  者:邵青[1] 冷超群[1] 

机构地区:[1]河北工业大学能源与环境工程学院,天津300401

出  处:《工业水处理》2014年第9期70-73,共4页Industrial Water Treatment

摘  要:通过胶体滴定法对固体和液体PAC产品进行实验,研究了PAC浓度、pH、盐基度等因素对电荷密度测定的影响规律;当实验pH为5.5左右,混凝剂质量浓度为10~25 mg/L,采用返滴定法可测定PAC的电荷密度。通过对湖水和染料水溶液的混凝脱色实验,表明电荷密度高的PAC产品浊度去除率、脱色率高。Solid and liquid PAC products are te sted by colloid titration. The rules of influences of PAC concentra-tion,pH,basicity and other factors on the determination of electric charge density are studied. When the pH tested is about 5.5,and coagulant mass concentration 10-25 mg/L,the back titration method could be adopted to determine the charge density of PAC. The coagulation and decolorization experiments of the lake water and the dye aqueous so-lution illustrate that the higher charge density of the PAC products is ,the higher the turbidity removing rate and the decolorization rate are.

关 键 词:混凝 聚合氯化铝PAC 胶体滴定法 电荷密度测定 

分 类 号:X703[环境科学与工程—环境工程]

 