Fenton氧化处理炼化废水中苯酚的实验研究  

Study on treatment of phenol in petroleum refining industry wastewater by fenton reagent

在线阅读下载全文

作  者:夏德强[1] 冯文成[1] 冷宝林[1] 甘黎明[1] 郑晓明[1] 

机构地区:[1]兰州石化职业技术学院石油化学工程系,甘肃兰州730060

出  处:《中国建材科技》2014年第4期63-64,92,共3页China Building Materials Science & Technology

基  金:甘肃省高等学校研究生导师科研项目(1216-03);甘肃省高校基本科研业务费专项资金资助项目(甘财教[2012]129号)

摘  要:通过单因素实验探索了Fenton氧化炼化废水中苯酚的最佳工艺条件。实验结果表明,Fenton试剂处理苯酚废水时,最佳氧化反应条件为:pH=3.5,反应温度为20℃,H2O2投加量为12mL·L-1,反应时间为30min,FeSO4·7H2O投加量为600mg·L-1。因此用Fenton氧化法处理含苯酚废水是一种非常有效的方法。Removal of phenol in petroleum refining industry wastewater by Fenton reagent oxidation was examined.The optimal operating conditions were determined by single factor experiments.The experiment results indicated that after 30min,the removal rate of phenol in petroleum refining industry wastewater rises to the top when pH value is 3.5,temperature is 20 ℃ ,H2O2 and FeSO4dosage is 12 mL . L^-1 and 600mg/L,respectively.So it is a very effective way to treat petroleum refining industry wastewater containing phenol using Fenton method.

关 键 词:FENTON试剂 苯酚 炼化废水 

分 类 号:X703.1[环境科学与工程—环境工程] TE991.2[石油与天然气工程—石油机械设备]

 