检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:蔡文娟[1] 杨鑫[2,3] 徐红卫[4] 刘洋[4] 梁华庚[5] 何楚楚[6] 林园[1] 丁明跃[7,1]
机构地区:[1]华中科技大学生命科学与技术学院生物医学工程系,图像信息处理与智能控制教育部重点实验室,武汉430074 [2]中山大学肿瘤防治中心,华南肿瘤学国家重点实验室,广州510060 [3]华中科技大学图像识别与人工智能研究所,多谱信息处理技术国防科技重点实验室,武汉430074 [4]郑州大学第五附属医院CT室,郑州450052 [5]华中科技大学同济医学院附属协和医院泌尿外科,武汉430074 [6]上海交通大学Med-X学院生物医学仪器研究所,上海200030 [7]湖北科技学院生物医学工程学院,咸宁437100
出 处:《中国生物医学工程学报》2014年第4期438-446,共9页Chinese Journal of Biomedical Engineering
基 金:国家自然科学基金国际合作项目(30911120497);国家科技支撑计划项目(2012BA113B02);湖北公益性科技研究项目(2012DCA06001)
摘 要:通过设计实验对超声体模的血管扩张功能(FMD)斑块高度进行了测量,对各种测量方法做出了定性与定量分析和比较,从而确定最佳的评估方法及软件,以用于颈动脉粥样硬化临床早期诊断和治疗。以颈动脉超声体模的实际尺寸作为金标准,对FMD斑块高度进行了测量,利用超声诊断仪专用软件和自行开发的分割软件,分别使用3种不同的测量方法:横向直接测量、横向间接测量和纵向直接测量,获取斑块的高度,并进行了比较和分析。结果表明,在横向间接测量方法中,超声诊断仪专用软件比自行开发的分割软件更为准确;而在横向直接测量和纵向直接测量中,自行开发的分割软件比超声诊断仪专用软件更为准确。自行开发的分割软件与超声诊断仪专用软件的测量结果在统计学上存在显著性差异(P<0.05),但两者相差的绝对值并不大(对应0.30、0.45、0.60 cm等3种斑块高度,小于0.02 cm)。总体来说,超声诊断仪专用软件和自行开发的分割软件测量结果都接近于金标准,但自行开发的分割软件的精确性优于超声诊断仪专用软件。The aim of this study was to find the most efficient measurement method used for the early diagnosis and treatment of carotid atherosclerosis in clinic. Measurement experiments based on the ultrasound phantom were designed to obtain the plaque heights for flow-mediated dilation (FMD). The quantitative analysis and comparison were made among these methods. Actual heights of simulated plaques in carotid ultrasound-phantom were used as the golden standard of the measurement. Measurement experiments for the plaques heights were designed for FMD evaluation. Plaque height measurements were implemented on two individual software of ultrasonography-based specialized software (USS) and our developed segmentation software (OSS), with three different measurement methods: transverse direct measurement (or transverse plaques height measurement, TPHM) ; transverse indirect measurement (or transverse plaques area measurement, TPAM); longitudinal direct measurement (or longitudinal plaques height measurement, LPHM). The measurement methods were evaluated according to the plaques heights. The measurement results between USS and OSS were statistically and significantly different ( P 〈 0.05 ), but the means of their difference are less than O. 02 cm with three different plaque heights. For TPAM, USS has a better performance on accuracy than OSS while for TPHM and LPHM, the conclusions were opposite. In conclusion, results obtained from the two measurements are both close to the golden standard, while the accuracy of OSS is higher than the USS.
关 键 词:动脉粥样硬化 血管扩张功能 超声体模 软件比较 评估
分 类 号:R318.08[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222