外科植入物用超高分子量聚乙烯中钛含量测定  被引量:1

Determination of Ti Element in Ultra-high Molecular Weight Polyethylene for Surgery Implants

在线阅读下载全文

作  者:马金竹[1] 马春宝[1] 姜熙[1] 李沅[1] 樊铂[1] 齐宝芬[1] 

机构地区:[1]国家食品药品监督管理局天津市医疗器械质量监督检验中心,天津300384

出  处:《中国医疗器械信息》2014年第9期32-35,共4页China Medical Device Information

基  金:国家科技支撑计划课题;课题编号:2012BAI22B01

摘  要:目的:建立外科植入物用超高分子量聚乙烯中杂质元素钛(Ti)含量的检测方法。方法:采用微波消解和电感耦合等离子体质谱仪(ICP-MS)测定消解液中钛元素。结果:钛元素标准曲线的R^2值大于0.9996,回收率为94.4%-96.4%,10次重复测定结果的相对标准偏差(RSD%)为1.3%。结论:所建立的方法精密度高、准确性好、干扰较少、快速简单,可用于超高分子量聚乙烯中钛元素的含量测定。Objective: To develop a method for determination of Ti element in Ultra-high molecular weight polyethylene for surgery Implants. Methods: Ti element were determined by microwave digestion and inductively coupled plasma mass spectrometry(ICP-MS). Result: The interrelation coefficient of calibration standards for Ti element was more than 0.9996, the recoveries of the addition standards for elements were between 94.4% and 96.4%. Conclusion: The results showed that this method was high precision and accorate, little disturbance, rapid determination, simple operation, It can be used for determination of Ti elements in Ultra-high molecular weight polyethylene.

关 键 词:ICP-MS 超高分子量聚乙烯  

分 类 号:R318.08[医药卫生—生物医学工程]

 