基于组合赋权法的农村低压配电网能效综合评价方法  被引量:11

Energy efficiency evaluation method of rural low-voltage distribution network based on combination weight method

在线阅读下载全文

作  者:韩晓慧[1] 杜松怀[1] 苏娟[1] 田贺平 屈博[2] 

机构地区:[1]中国农业大学信息与电气工程学院,北京100083 [2]中国电力科学研究院用电与能效研究所,北京100192

出  处:《农业工程学报》2014年第16期195-202,共8页Transactions of the Chinese Society of Agricultural Engineering

基  金:河南省科技计划项目(11201303451)

摘  要:为能够深入了解农村低压配电网整体能效情况,在分析配电网节能指标现状的基础上,建立了农村低压配电网能效评价指标体系和综合评价模型。首先,依据相关标准规范,从电网结构、电网设备、电能质量等方面建立了一套适合农村低压配电网能效特点的评价指标体系;然后,确定了单项能效指标的计算方法并提出了基于主成分分析与层次分析法相结合的农村低压配电网能效综合评价模型,该方法克服了单一赋权法的不足,实现了能效指标的客观性与专家定性分析的主观性的有机结合,使评估结果更加合理;最后,通过算例验证了评价方法的有效性和可行性,对今后中国农村低压配电网实施节电改造和节能考核提供参考。Aimed at understanding the overall energy efficiency level of rural low-voltage distribution network, and on the basis of analyzing current research on energy saving indexes of distribution network, the energy efficiency evaluation index system and evaluation model of rural low-voltage distribution network were established in this article. Firstly, according to relevant standards and rules, a set of comprehensive index system for evaluating energy efficiency of rural low-voltage distribution network was established. The index system consisted of seven second grade indexes, such as the electric network structure, network equipment, power quality, network loss, economic operation of power network, reactive power compensation and distributed generation. Particularly, electric network structure index included 4 third grade indexes: the proportion of distribution transformer located at the load center and 380V line power radius beyond the standard, the percentage of small section for 380 V line and connecting line;the network equipment index contained 3 third grade indexes:the ratio of efficient type distribution transformer, non-standardized distribution transformer capacity and energy-efficient low-voltage line; the power quality index consisted of 4 third grade indexes: the qualified rate of 380 V three-phase load unbalance degree, 380/220 V voltage monitoring point, 380V voltage and current total harmonic distortion; the network loss index included 4 third grade indexes: the comprehensive loss rate of distribution transformer and low voltage, the number of serious exceed the standard rate of loss rate for single distribution transformer and low voltage;the economic operation of power network index consisted of one third grade index that distribution transformer load rate of interval number in the economic;the reactive power compensation index included 4 third grade indexes: reactive power compensation device installation and operation rate, distribution transformer monthly average power factor qualificat

关 键 词:农村地区 主成分分析 层次分析法 低压配电网 能效指标体系 

分 类 号:TM926[电气工程—电力电子与电力传动]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象