新型心肌灌注显像剂^99Tc^m-N-DBODC5诊断冠心病的临床价值  被引量:1

Clinical study of ^99Tc^m-N-DBODC5 as a novel myocardial perfusion imaging agent for the diagnosis of coronary artery disease

在线阅读下载全文

作  者:马海彦[1] 李思进[1] 刘建中[1] 武志芳[1] 刘海燕[1] 郭小闪[1] 卫华[1] 胡光[1] 王进[1] 

机构地区:[1]山西医科大学第一医院核医学科,太原030001

出  处:《中华核医学与分子影像杂志》2014年第5期349-353,共5页Chinese Journal of Nuclear Medicine and Molecular Imaging

基  金:山西省青年科技研究基金(2009021043-3)

摘  要:目的 探讨[二(二甲氧丙基膦基乙基)-乙氧乙胺]-[二(氧-乙氧乙基)二硫代氨基]锝氮配合物(^99Tc^m-N-DBODC5)对可疑冠心病患者的临床诊断价值.方法 将2010年10月至2012年10月间46例可疑冠心病患者[男31例,女15例,平均年龄60岁]按就诊先后顺序编号,同一患者随机分配进行^99Tc^m-N-DBODC5和^99Tc^m-MIBI运动-静息MPI检测冠心病及病变血管,2种显像剂的MPI在1周内完成,并在4周内行CAG.以CAG结果为“金标准”,^99Tc^m-N-DBODC5和^99Tc^m-MIBIMPI结果分别与其进行一致性检验,不同显像剂诊断效能的比较行χ^2检验.结果 46例可疑冠心病患者中,CAG阳性29例,阴性17例.^99Tc^m-N-DBODC5和^99Tc^m-MIBI MPI诊断冠心病的灵敏度均为86% (25/29),特异性分别为88%(15/17)和65%(11/17),两者诊断冠心病效能差异无统计学意义(χ^2=2.62,P>0.05);138支冠状动脉血管中,CAG阳性48支,阴性90支.^99Tc^m-N-NDBODC5与^99Tc^m-MIBI MPI诊断病变血管效能差异也无统计学意义(χ^2=3.79,P>0.05).诊断冠心病方面,^99Tc^m-N-DBODC5 MPI与CAG结果的一致性较好(Kappa=0.73),^99Tc^m-MIBI MPI与CAG结果的一致性中等(Kappa=0.52).结论 ^99Tc^m-N-DBODC5对冠心病患者具有一定诊断价值,可作为心肌灌注显像剂应用于临床.Objective To investigate the clinical value of ^99Tc^m-(bis(dimethoxypropylphosphinoethyl)-ethoxyethylamine)-(bis(N-ethoxyethyl)-dithiocarbamato nitride (^99Tc^m-N-DBODC5) for the detection of coronary artery disease (CAD).Methods From October 2010 to October 2012,46 patients with suspected CAD (31 males,15 females; average age:60 years) were recruited.They all underwent stressrest MPI using both ^99Tc^m-N-DBODC5 and ^99Tc^m-MIBI within l week.CAG was carried out within 1 month after MPI and chosen as the gold standard.The diagnostic accordance rate between MPI and CAG were analyzed using Kappa test.The diagnostic efficiency of ^99Tc^m-N-DBODC5 and ^99Tc^m-MIBI MPI was compared byχ^2 test.Results Among the 46 patients,29 were positive and 17 were negative for CAD by CAG.The sensitivity and specificity in the detection of CAD were 86% (25/29) and 65% (11/17) for ^99Tc^m-MIBI MPI,86% (25/29) and 88% (15/17) for ^99Tc^m-N-DBODC5 MPI (χ^2=2.62,P〉0.05),respectively.Among the 138 vessels,48 were positive and 90 were negative on CAG.The vessel-based sensitivity,specificity and accuracy for the detection of stenosis were not significantly different between ^99Tc^m-N-DBODC5 and ^99Tc^m-MIBI (χ^2=3.79,all P〉0.05).The accordance between ^99Tc^m-N-DBODC5 MPI and angiography was very good (Kappa=0.73) and moderate for ^99Tc^m-MIBI MPI (Kappa=0.52).Conclusion ^99Tc^m-N-DBODC5 might have a potential role as a MPI agent for the diagnosis of CAD.

关 键 词:冠状动脉疾病 体层摄影术 发射型计算机 单光子 DBODC5 MIBI 

分 类 号:R817.4[医药卫生—影像医学与核医学] R541.4[医药卫生—放射医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象